10 sample questions for the Certified EKG Technician Exam, with the correct answer and an explanation for each. No account needed. Try each one before you open the answer.
Sections covered on the exam: Safety, Infection Control and HIPAA, Scope of Practice, Ethics, Communication and the EHR, Vital Signs, Cardiopulmonary Compromise and BLS, EKG Equipment, Supplies and Machine Settings, Skin Preparation, Positioning and 12-Lead Placement, Patient Instruction for Stress Tests and Ambulatory Monitors, Artifacts, Lead Verification and Tracing Documentation, Ambulatory, Telemetry, Stress Test and Special Lead Placement, Sinus, Atrial, Junctional Rhythms and Heart Blocks, Ventricular Rhythms, Pacemakers, Ischemia and Emergencies.
Question 1 · Safety, Infection Control and HIPAA
Answer: D. Decline, because she has no work-related need to see the tracing
Under the HIPAA Privacy Rule, staff may access protected health information only when they need it for their job (the minimum necessary standard). A promise of privacy or a verbal summary is still an improper disclosure, and working in the same clinic does not give access to every record.
Question 2 · Vital Signs, Cardiopulmonary Compromise and BLS
Answer: B. As possible cardiac warning signs that should be reported
Women, older adults and people with diabetes often have atypical cardiac symptoms such as fatigue, shortness of breath, nausea or indigestion instead of classic chest pain. The technician recognizes these as possible cardiopulmonary compromise and reports them to the nurse or provider rather than dismissing them.
Question 3 · EKG Equipment, Supplies and Machine Settings
Answer: C. Paper speed 25 mm/s and gain 10 mm/mV
Standard settings are a paper speed of 25 mm/s and a gain of 10 mm/mV, the values every interval and amplitude norm is based on. A speed of 50 mm/s or a gain of 5 or 20 mm/mV is used only for specific reasons and must be noted on the tracing.
Question 4 · Patient Instruction for Stress Tests and Ambulatory Monitors
Answer: A. Just below the right clavicle
The white (right arm) electrode goes just under the right clavicle, the black (left arm) electrode goes under the left clavicle and the red (left leg) electrode goes on the lower left rib cage or abdomen. The lower right area is used for the green electrode in a 5-lead system.
Question 5 · Ambulatory, Telemetry, Stress Test and Special Lead Placement
Answer: A. 0.04 second
At 25 mm/s, each 1 mm small box equals 1/25 of a second, or 0.04 second. A large box (5 small boxes) equals 0.20 second; 0.02 second would apply at 50 mm/s, and 0.10 is a vertical voltage value (mV), not a time.
Question 6 · Safety, Infection Control and HIPAA
Answer: A. Do not post it, because the details could still identify the patient
Dates, times, room numbers and other details can identify a patient, so the photo is still protected health information and posting it would violate the HIPAA Privacy Rule. Limiting the audience or waiting does not make the disclosure acceptable; PHI should never be posted on social media.
Question 7 · Vital Signs, Cardiopulmonary Compromise and BLS
Answer: A. 15 compressions to 2 breaths
For children and infants, two rescuers use a 15:2 ratio, while a single rescuer uses 30:2. The 30:2 ratio applies to all adults and to one-rescuer pediatric CPR, and the other ratios are not part of current BLS guidelines.
Question 8 · EKG Equipment, Supplies and Machine Settings
Answer: D. Twice as wide, and the speed must be noted
Doubling the paper speed spreads each complex over twice as much paper, making waves twice as wide and easier to separate at fast rates; the speed must be noted so intervals are not misread. Paper speed does not change height, and the change affects every lead, not just the rhythm strip.
Question 9 · Patient Instruction for Stress Tests and Ambulatory Monitors
Answer: D. Lower left rib cage or abdomen
The red (left leg) electrode goes on the lower left rib cage or abdomen; 'smoke over fire' reminds that black sits above red on the left side. White goes below the right clavicle, black below the left clavicle, and the right sternal border is the usual brown chest electrode site in a 5-lead system.
Question 10 · Ambulatory, Telemetry, Stress Test and Special Lead Placement
Answer: C. 1.5 mV
At standard gain each small box vertically equals 0.1 mV, so 15 x 0.1 = 1.5 mV (15 mm / 10 mm per mV). A value of 3.0 mV would apply if the machine were at half gain (5 mm/mV), 15 mV mistakes millimeters for millivolts, and 0.6 mV confuses height with time.
TTP Prep has 200 EKG Technician (CET) practice questions with explanations, timed and mock-exam modes, 321 flashcards, interactive lessons, a printable cheat sheet and a readiness score. Start free, no card needed.