10 sample questions for the Contractor's General Building, with the correct answer and an explanation for each. No account needed. Try each one before you open the answer.
Sections covered on the exam: Planning and Estimating, Framing and Structural Components, Core Trades, Finish Trades, Safety.
Question 1 · Planning and Estimating
Answer: B. California Building Code
The California Residential Code is limited to detached one- and two-family dwellings and townhouses not more than three stories above grade plane, with their accessory structures. A four-unit apartment building is a Group R-2 occupancy and is designed under the California Building Code. CALGreen adds green-building measures but does not set structural or fire-safety design.
Question 2 · Framing and Structural Components
Answer: C. 13 ft 5 in.
Run = span ÷ 2 = 12 ft. Rise = 12 ft × 6/12 = 6 ft. Line length = √(12 × 12 + 6 × 6) = √180 = 13.42 ft, about 13 ft 5 in. Using the full 24 ft span as the run gives 26 ft 10 in., and simply adding rise to run gives 18 ft.
Question 3 · Core Trades
Answer: C. 9,600 W
A continuous load may not exceed 80% of the branch-circuit rating under the California Electrical Code. 50 A × 0.80 = 40 A; 40 A × 240 V = 9,600 W. Skipping the 80% step gives 12,000 W, applying it twice gives 7,680 W, and using 120 V gives 4,800 W.
Question 4 · Core Trades
Answer: C. STC 50
The California Building Code requires walls, partitions, and floor-ceiling assemblies that separate dwelling units from each other or from public areas to have an STC of at least 50 when laboratory tested, or 45 when field tested. Floor-ceiling assemblies must also meet an impact insulation class (IIC) of 50, or 45 if field tested.
Question 5 · Finish Trades
Answer: C. 44 in.
The California Residential Code requires the bottom of the clear opening of an emergency escape and rescue opening to be not more than 44 in. above the floor. The opening must also meet minimum net clear area, height, and width dimensions, and it must be operable from the inside without keys or tools.
Question 6 · Planning and Estimating
Answer: B. Bottom of footing to top of wall
The permit exemption in the California Residential Code applies to retaining walls not over 4 ft in height measured from the bottom of the footing to the top of the wall, unless the wall supports a surcharge. A wall with 4 ft of exposed face is taller than that once the footing is counted, so it needs a permit.
Question 7 · Framing and Structural Components
Answer: C. 720 sq in.
Total net free area = 1,500 ÷ 150 = 10 sq ft. Convert: 10 × 144 = 1,440 sq in. Half at the soffits = 720 sq in. Stopping at 1,440 sq in. ignores the split, using a 1-to-300 ratio gives 360 sq in., and multiplying square feet by 12 instead of 144 gives 60 sq in.
Question 8 · Core Trades
Answer: B. 4,800 W
Current: I = E ÷ R = 240 V ÷ 12 ohms = 20 A. Power: P = E × I = 240 V × 20 A = 4,800 W. Multiplying volts by ohms gives 2,880, using 120 V gives 1,200, and squaring the voltage without dividing by the resistance gives 57,600.
Question 9 · Core Trades
Answer: A. Waterproofing membrane up to finished grade
The California Residential Code requires dampproofing on foundation walls that retain earth and enclose interior space, but where a high water table or other severe soil-water condition is known to exist, the wall must be waterproofed up to finished grade. Dampproofing resists soil moisture only; it does not resist water under hydrostatic pressure.
Question 10 · Finish Trades
Answer: A. Self-closing and self-latching hardware
The California Residential Code allows a 1-3/8 in. solid wood door, a 1-3/8 in. solid or honeycomb-core steel door, or a 20-minute fire-rated door between the garage and the dwelling. California also requires the door to be self-latching and equipped with a self-closing or automatic-closing device.
TTP Prep has 200 Contractor's General Building practice questions with explanations, timed and mock-exam modes, 258 flashcards, interactive lessons, a printable cheat sheet and a readiness score. Start free, no card needed.